Tubes which have been evacuated usually are sealed off while they are
still connected to the vacuum pump. The connection should be through a
small, rather thick-walled tube. When this is to be sealed, it is slowly
heated toward the softening point. As the glass just begins to soften,
the air-pressure will force it in, and care must be taken that the
softening is uniform over the whole circumference of the tube. As the
shrinking goes on, the tube is gently drawn out to make a thick-walled
cone at that place, and the end is drawn off as soon as the tube is
sealed. The principal point to be guarded is the thickness of the walls
of the cone, and uniform heating. A thin place or a hot place will give
way under the air-pressure and be sucked into the tube.
This piece is part of Laboratory Manual Of Glass-blowi. Explore the full collection for more from this work.