The Arts & Craft Library Part of the Informational Site Network

Capillary Tubing

This is commonly used in many forms of apparatus for gas analysis, and

This is commonly used in many forms of apparatus for gas analysis, and

one is often called upon to join two pieces or to make a tee on it. The

methods are nearly the same as with other tubing, except that more care

and patience are required. The work must be done much more slowly on

account of the thickness of the walls, and open ends of the tube must

always be enlarged before joining them to anything. This is best done by

carefully sealing the end and then blowing, with several suitable

reheatings, to form a pear-shaped bulb as in a, Fig. 14. The end of

this is then heated and blown off, and the piece is ready to be joined

to another similar end, or to a piece of ordinary tubing if desired. The

joints are best not blown too much, as thick walls shrink very slowly.

Much may be done by gently pushing the tube together or pulling it apart

in the flame, to remove lumps and irregularities. It is necessary that

the bore of the joint be approximately that of the main tube, and care

must be taken that the latter is not constricted at the point where the

joint begins.

Especial care must be taken to warm the tube slowly when starting and

cool it slowly when through, as the thick walls frequently crack if not

carefully handled. For this reason the whole neighborhood of the joint

must be heated somewhat so that there may not be stresses set up between

the heated and unheated portions.

In making the tee (b, Fig. 14) the inability to blow the joint makes

itself decidedly felt, but if the side tube is properly enlarged as

previously described, a good joint can be made by alternately pulling

and pushing on the end of the side tube, and shrinking well.

Very fine capillary tubing should be blown with a rubber bulb instead of

the mouth, so as not to get moisture into the tube. The rubber bulb may

also be used to advantage on some of the coarser capillary tubing.

When a bulb is to be joined to a piece of capillary tubing, the joint is

preferably made before blowing the bulb, and will then be taken up a

little way on the bulb during the process. Care must of course be taken

not to constrict the capillary; the pear-shaped bulb blown on the end

(a, Fig. 14) may well extend back a little further than usual into the

tube so as to prevent this. If a bulb is required in the middle of a

capillary tube, the latter is usually best cut and a piece of ordinary

tubing of suitable size sealed in to provide material for the bulb.

Source

This piece is part of Laboratory Manual Of Glass-blowi. Explore the full collection for more from this work.

Previous Glass Rod Next Exercise No 9 - Sealing A Tube Through Another Tube