This is commonly used in many forms of apparatus for gas analysis, and
one is often called upon to join two pieces or to make a tee on it. The
methods are nearly the same as with other tubing, except that more care
and patience are required. The work must be done much more slowly on
account of the thickness of the walls, and open ends of the tube must
always be enlarged before joining them to anything. This is best done by
carefully sealing the end and then blowing, with several suitable
reheatings, to form a pear-shaped bulb as in a, Fig. 14. The end of
this is then heated and blown off, and the piece is ready to be joined
to another similar end, or to a piece of ordinary tubing if desired. The
joints are best not blown too much, as thick walls shrink very slowly.
Much may be done by gently pushing the tube together or pulling it apart
in the flame, to remove lumps and irregularities. It is necessary that
the bore of the joint be approximately that of the main tube, and care
must be taken that the latter is not constricted at the point where the
joint begins.
Especial care must be taken to warm the tube slowly when starting and
cool it slowly when through, as the thick walls frequently crack if not
carefully handled. For this reason the whole neighborhood of the joint
must be heated somewhat so that there may not be stresses set up between
the heated and unheated portions.
In making the tee (b, Fig. 14) the inability to blow the joint makes
itself decidedly felt, but if the side tube is properly enlarged as
previously described, a good joint can be made by alternately pulling
and pushing on the end of the side tube, and shrinking well.
Very fine capillary tubing should be blown with a rubber bulb instead of
the mouth, so as not to get moisture into the tube. The rubber bulb may
also be used to advantage on some of the coarser capillary tubing.
When a bulb is to be joined to a piece of capillary tubing, the joint is
preferably made before blowing the bulb, and will then be taken up a
little way on the bulb during the process. Care must of course be taken
not to constrict the capillary; the pear-shaped bulb blown on the end
(a, Fig. 14) may well extend back a little further than usual into the
tube so as to prevent this. If a bulb is required in the middle of a
capillary tube, the latter is usually best cut and a piece of ordinary
tubing of suitable size sealed in to provide material for the bulb.
This piece is part of Laboratory Manual Of Glass-blowi. Explore the full collection for more from this work.