Very often it is necessary to seal platinum wire into the wall of a

Very often it is necessary to seal platinum wire into the wall of a

tube. Professional glass-blowers usually use a special sort of glass

("Einschmelzglas") which is usually a lead glass, and is made of such

composition that it has the same or practically the same coefficient of

expansion as platinum. A little globule of this glass is sealed into the

tube in such a way that it joins the platinum to the glass of the tube.

To do this, the small globule of special glass is fused on the platinum

wire at the proper point and the tube into which the wire is to be

sealed is heated and a small tail drawn out at the point where the wire

is to be inserted. The lump of the special glass should be from 3/32 to

1/8 inch in diameter, and the tail drawn on the tube should have a

slightly less diameter at the point (about 1/8 inch or less from the

tube) where it is cut off. There are now two ways of sealing in the

wire. (1) The wire with the globule of glass is placed inside the tube

and the latter revolved until the end of the wire sticks out of the cut

tail (a, Fig. 18). The latter is now gently heated, and the two glass

surfaces fused together, taking care to use only the end of the hissing

flame, if the special glass contains lead. (See Chapter I, page 1.) The

whole circumference of the tube is then heated and annealed carefully.

(2) The end of the wire which is to be outside the tube is attached to

the end of a thin scrap of glass, by heating the glass and thrusting

the wire into it a very little way. Using this piece of glass as a

handle, the wire is inserted in the cut tail (b, Fig. 18) and the

globule brought near to the end of the tail. (If the main tube is cold,

it must of course first be warmed.) With the end of the hissing flame,

as in the first method, the globule of glass is melted and the end of

the tail softened. The wire is now pushed into place, the handle removed

by heating the end and withdrawing it, and the tail reheated a little if

necessary to make it shrink back into line with the walls of the tube.

The whole circumference of the tube is heated at that point and annealed

as usual.

The use of this special glass is not absolutely necessary if the

platinum wire is small (1/4 millimeter or less in diameter), and in fact

it is often better in such cases not to use it, unless the apparatus is

to be subjected to a very high vacuum. On small tubes, especially, it is

undesirable to use the special glass, as a lump of it will usually cause

the tube to crack on cooling. When such glass is not at hand or is not

to be used, the procedure is altered somewhat. The tail which is drawn

out is very fine, having only a sufficient diameter so that when it is

cut off the wire can be inserted in it. Such a fine tail is readily made

by heating a small spot on the tube, touching it with a warm platinum

wire, removing from the flame and drawing out the tail with the wire.

After cutting off the tail the wire is inserted in it, being held on a

scrap of glass as in the previous case, and the wire and tail heated

until the latter shrinks back into line with the walls of the tube. If

too great shrinkage occurs, the place may be blown out gently after

reheating. Thus the wire is sealed through the wall of the tube without

changing the thickness of the latter, and consequently without

developing undue stresses at that point. Such a joint must of course be

carefully reheated and annealed. With fine platinum wire there is very

little risk of the tube cracking if care is taken to avoid formation of

any lump and to reheat the whole circumference of the tube at that

point.

Any glass adhering to the end of the platinum wire, where the scrap of

glass was sealed on for a handle, may be removed when the glass has

cooled by crushing it carefully with a pair of pliers.