Most students learn this the first day of their laboratory work in chemistry, but few take pains to do it well. The tube should be heated in the flame of a Bunsen burner, or blast lamp (preferably the latter) until it is very soft. During this time it must be continuously rotated about its axis, and so held that the edges of the heated zone are sharply defined; <em>i.e.</em>, it should not be allowed to move back and forth along its own axis. When so hot that it cannot longer be held in shape, the tube is removed from the flame, and the ends slowly and regularly drawn apart, <em>continuing the rotation of the tube about its axis</em>. By regulating the rate of drawing and the length of tube heated, the desired length and diameter of capillary may be obtained. The tube should always be rotated and kept in a straight line until the glass has set, so that the capillary may have the same axis as the main tube. This capillary or "tail" is often a very necessary handle in glass-blowing, and if it is not straight and true, will continually make trouble.</p>
<p>In drawing out very large tubing, say from one to two inches in diameter, it is often necessary to draw the tube <em>in the flame</em>, proceeding very slowly and at a lower temperature than would be used with small tubing. This is partly on account of the difficulty of heating large tubing uniformly to a high temperature, and partly in order to prevent making the conical part of the tube too thin for subsequent operations.</p>
This piece is part of Laboratory Manual Of Glass-blowi. Explore the full collection for more from this work.